NEC uPD78056Y User Manual

Page 274

Advertising
background image

274

CHAPTER 14 A/D CONVERTER

Figure 14-6. A/D Converter Basic Operation

A/D conversion operations are performed continuously until bit 7 (CS) of ADM is reset (0) by software.

If a write to the ADM is performed during an A/D conversion operation, the conversion operation is initialized, and

if the CS bit is set (1), conversion starts again from the beginning.

After RESET input, the value of ADCR is undefined.

SAR

ADCR

INTAD

A/D Converter
Operation

Sampling Time

Sampling

A /D Conversion

Conversion

Time

Undefined

80H

C0H

or

40H

Conversion
Result

Conversion
Result

Advertising