CHAPTER 21 INTERRUPT AND TEST FUNCTIONS

7

0

Symbol

KRM

6

0

5

0

4

0

3

0

2

0

<1>

KRMK

<0>

KRIF

Address

FFF6H

02H

When
Reset

R/W

R/W

0

1

Key Return Signal

Not detected

Detected (port 4 falling edge detection)

KRIF

0

1

Standby Mode Control by Key Return Signal

Standby mode release enabled

Standby mode release disabled

KRMK

(3) Key return mode register (KRM)

This register is used to set enable/disable of standby function clear by key return signal (port 4 falling edge

detection).

KRM is set with a 1-bit or 8-bit memory manipulation instruction.

RESET input sets KRM to 02H.

Figure 21-21. Key Return Mode Register Format

Caution

When port 4 falling edge detection is used, be sure to clear KRIF to 0 (not cleared to 0

automatically)

21.5.2 Test input signal acknowledge operation

(1) Internal test signal

The internal test input signal (INTWT) is generated with watch timer overflow, and the WTIF flag is set. If not

masked with bit 7 (WTMK) of interrupt mask flag register 1L (MK1L) at this time, a standby release signal is

generated. The watch function is available by checking the WTIF flag using a shorter cycle than the watch

timer overflow cycle.

(2) External test signal

When a falling edge (external test input signal) is input to the port 4 (P40 to P47) pins, KRIF is set. If not masked

with bit 1 (KRMK) of key return mode register (KRM) at this time, a standby release signal is generated. If

port 4 is used as key matrix return signal input, whether or not a key input has been applied can be checked

from the KRIF status.