CHAPTER 18 SERIAL INTERFACE CHANNEL 1

(b) Basic transmission mode

In this mode, the specified number of 8-bit unit data are transmitted.

Serial transfer is started when any data is written to the serial I/O shift register 1 (SIO1) while bit 7 (CSIE1)

of the serial operating mode register 1 (CSIM1) is set to 1.

The interrupt request flag (CSIIF1) is set upon completion of transmission of the last byte. However, judge

the completion of the automatic transmission/reception not with CSIIF1 but bit 3 (TRF) of the automatic

data transmit/receive control register (ADTC).

If receive operation, busy control and strobe control are not executed, the P20/SI1, P23/STB and P24/

BUSY pins can be used as normal input/ports.

Figure 18-11 shows the basic transmission mode operation timings, and Figure 18-12 shows the operation

flowchart. Figure 18-13 shows the operation of the buffer RAM when 6 bytes of data are transmitted or

received.

Figure 18-11. Basic Transmission Mode Operation Timings

Cautions 1. Because, in the basic transmission mode, the automatic transmit/receive function

reads data from the buffer RAM after 1-byte transmission, an interval is inserted till

the next transmission. As the buffer RAM read is performed at the same time as CPU

processing, the maximum interval is dependent upon CPU processing and the value

of the automatic data transmit/receive interval specify register (ADTI) (see (5)

"Automatic data transmit/receive interval").

2. When TRF is cleared, the SO1 pin becomes low level.

Remark

CSIIF1 : Interrupt request flag

TRF

: Bit 3 of automatic data transmit/receive control register (ADTC)

SCK1

SO1

D7 D6 D5 D4 D3 D2 D1 D0

D7 D6 D5 D4 D3 D2 D1 D0

CSIIF1

TRF