Specifications
General Specifications

142

13163L-001 Rev. A

Z4Mplus/Z6Mplus User Guide

1/18/06

General Specifications

General Specifications

Z4Mplus

Z6Mplus

Height

13.3 in.

338 mm

13.3 in.

338 mm

Width

10.9 in.

277 mm

13.4 in.

341 mm

Depth

18.7 in.

475 mm

18.7 in.

475 mm

Weight (without options)

32.4 lbs.

14.7 kg

34.7 lbs.

16 kg

Electrical

90-265 VAC, 47-63 Hz, 5 Amps
(fused)

90-265 VAC, 47-63 Hz, 5 Amps
(fused)

Temperature

Operating

40° to 104°F

5° to 40°C

40° to 104°F

5° to 40° C

Storage

–40° to 140°F

–40° to 60°C

–40° to 140°F

–40° to 60°C

Relative
Humidity

Operating

20% to 85%, non-condensing

20% to 85%, non-condensing

Storage

5% to 85%, non-condensing

5% to 85%, non-condensing

Communication Interface

RS-232/CCITT V.24 serial data interface; 110 to115000 baud, parity,
bits/character, 7 or 8 data bit, and XON-XOFF, RTS/CTS or DTR/DSR
handshake protocol required. 750mA at 5V from pin 9.

8-bit parallel data interface; supports IEEE 1284 bi-directional parallel, ECP
and nibble mode compliant. Error detection CRC protocol.

Memory

8 MB DRAM memory (3.5 MB user available)

2 MB flash memory