Print Sensor Profile
The sensor profile may be used to troubleshoot registration problems that
may be caused when the media sensor detects preprinted areas on the media
or if it experiences difficulty in determining web location.

Figure 31

shows a sensor profile. If the sensitivity of the media and/or

ribbon sensors must be adjusted, use

Calibrate Media and Ribbon Sensor

Sensitivity on page 84

to adjust sensor sensitivity.

Figure 31 • Sensor Profile

To print a sensor profile:

1.

Press

SELECT

to select the parameter.

2.

Press

PLUS (+)

to start this standard calibration procedure and print a

media sensor profile.

3.

Press

SELECT

to accept any changes and deselect the parameter.