Zebra Technologies Z4Mplus User Manual

Page 96

Advertising
background image

Configuration
Control Panel LCD Displays

88

13163L-001 Rev. A

Z4Mplus/Z6Mplus User Guide

1/18/06

Set Communications Mode
The communication diagnostics mode is a troubleshooting tool for
checking the interconnection between the printer and the host computer.
When

DIAGNOSTICS

is selected, all data sent from the host computer to

the printer prints as straight ASCII characters, with the hex value below the
ASCII text. The printer prints all characters received, including control
codes, like CR (carriage return). A sample printout is shown in

Communications Diagnostics Test on page 132

.

Notes on diagnostic printouts are defined as follows:

• FE indicates a framing error.

• OE indicates an overrun error.

• PE indicates a parity error.

• NE indicates noise.

Default: NORMAL MODE

Selections: NORMAL MODE, DIAGNOSTICS

To change the value shown:

1.

Press

SELECT

to select the parameter.

2.

Press

PLUS (+)

or

MINUS (-)

to toggle between the options.

3.

For any errors, check that your communication parameters are correct.

4.

Set the print width equal to or less than the label width used for the test.
See

Set Print Width on page 77

for more information.

5.

Press

SELECT

to accept any changes and deselect the parameter.

Set Control Prefix Character
The printer looks for this two-digit hex character to indicate the start of a
ZPL/ZPL II control instruction. The “H” that is displayed indicates
Hexadecimal and is not part of the value.

Note •

Do not use the same hex value for the control, format, and

delimiter character. The printer must see different characters to
work properly.

Default: 7E (tilde—displayed as a black square)

Range: 00 to FF

To change the value shown:

1.

Press

SELECT

to select the parameter.

2.

Press

MINUS (-)

to move to the next digit position.

3.

Press

PLUS (+)

to increase the value of the digit.

4.

Press

SELECT

to accept any changes and deselect the parameter.

Table 9 • Printer Parameters (Page 16 of 23)

Parameter

Action/Explanation

COMMUNICATIONS
- NORMAL MODE +

CONTROL PREFIX

- < >7EH +

Advertising