2 status info – Accusys ExaRAID GUI User Manual

Page 126

Advertising
background image

Using the LCD Consolel

3-3

3.2.2 Status info

When the system is ready, the system information and background task
messages are displayed sequentially every two seconds. See the button
functions as below.

UP/DOWN: Scroll up/down the message.

ESC: Clear the message and enter the menu (password may be required).

ENT: Enter the password (if required).

UP+DOWN: Clear all status info and restart to display all the status
messages.

Line 1 shows messages, and Line 2 shows the disk status. Messages to be
displayed on the LCD panel can be customized by users. The supported
status info is listed below:

Status Info

Message

Note

Product name

product name

Expansion name

Expansion #x

#x: Expansion ID
Up to four expansions can
be added.

Date and time

hh:mm MM/DD YY

IP address

xxx.xxx.xxx.xxx

BP FAN[x] rpm

FANx xxxxxrpm

Expansion FAN[x] rpm

FAN#x xxxxxrpm

Controller voltage +3.3V

[A] 3.3V: xx.xx

3.3V, 5V, and 12V status
on controller A or B

* [A] denotes controller A;
[B] denotes controller B.

Controller voltage +5V

[A] 5.0V: xx.xx

Controller voltage +12V

[A] 12.0: xx.xx

BP voltage +3.3V

[BP] 3.3V: xx.xx

3.3V, 5V, and 12V status
on backplane

BP voltage +5V

[BP] 5.0V: xx.xx

BP voltage +12V

[BP] 12.0: xx.xx

Expansion voltage
sensor[x]

VOLT#x: xx.xx

Controller temperature
sensor[x]

[A] TEMPx: xx.xC

Both Celsius (C) and
Fahrenheit (F) are
supported. Users can
customize the
temperature scale for the
display.

* [A] denotes controller A;
[B] denotes controller B.

BP temperature sensor[x]

[BP] TEMPx: xx.xC

BP average temperature

[BP] AVG: xx.xC

Expansion temperature
sensor[x]

TEMP#x: xx.xC

Power[x] is %s

Powx: %s

%s: Good, Warning, Error,
OFF

Expansion power[x] is %s

Pow#x: %s

Table 3-1 List of status messages

Advertising