5 miscellaneous – Accusys ExaRAID GUI User Manual

Page 168

Advertising
background image

Using the CLI Commands

4-37

4.9.5 Miscellaneous

Command

ctllist

Synopsis

ctllist ctlx [-r]

Description

List the controller-related information.

Parameters

[-r] (for redundant controller only): Show internal controller
status

Command

sysdiag

Synopsis

sysdiag start/stop nvram/dram/fcloopback/led/disk all/
hdds

Description

Starts or stops one of the following self tests:

• NVRAM R/W test: The test will be conducted only

once when controller is restarted.

• DRAM R/W test: The test will be conducted only once

when controller is restarted.

• FC loopback test: The test will be conducted

immediately stops it or the controller restarts.

• LED test: The test will be conducted immediately and

stop when the user manually stops it or the controller
restarts.

• Disk R/W test: This test can only be performed on

unused disks. The test will be conducted
immediately. It shall stop on error or when the user
manually stops it or the controller restarts.

Command

sysdiaglist

Synopsis

sysdiaglist

Description

Display the status of self tests including the following
information

Command

restart

Synopsis

restart [-h] [-c ctlx] [-b] [-e]

Description

Restart or halt the controller.

Parameters

[-h]: halt without restart

[-c ctlx] (for redundant controller only): restart only one
controller

[-b] (for redundant controller only): effective for both
controllers

[-e]: effective for all external enclosures

Advertising