8 uninterruptible power supply – Accusys ExaRAID GUI User Manual

Page 156

Advertising
background image

Using the CLI Commands

4-25

4.5.8 Uninterruptible power supply

Command

enclist conf

Synopsis

enclistconf

Description

List enclosure configurations.

Command

encidentify

Synopsis

encidentify on/off encx

Description

Enable or disable identifying the enclosure with a visual
indication. This command is applicable only when enclosure
visual indication hardware is available.

Command

encfwupdate

Synopsis

enfwupdate encx firmware.bin

Description

Update the firmware of the controller in an external
enclosure with the specified firmware file.

Command

upscontrol

Synopsis

upscontrol on/off

Description

Enable or disable UPS support.

Command

upslist

Synopsis

upslist

Description

List UPS information.

Command

upsconfig

Synopsis

upsconfig [-d YY/MM/DD] [-l xxsec] [-r xx%] [-s xxsec]
[-b xxsec]

Description

Set UPS configurations. At least one option should be
assigned.

Parameters

[-d YYYY/MM/DD]: date of last battery replacement

[-l xxsec]: low battery runtime threshold

[-r xx%]: minimum battery charge capacity before restart

[-s xxsec]: UPS delay power off in seconds

[-b xxsec]: UPS delay power on in seconds