3 emergent info, 4 background task messages – Accusys ExaRAID GUI User Manual

Page 127

Advertising
background image

Using the LCD Console

3-4

3.2.3 Emergent info

When an emergent event occurs, you can read the message on the LCD.
This state is held until every event is confirmed. See the function buttons as
below.

UP/DOWN: Scroll up/down the message.

ENT: Confirm (clear) the message. (not supported in current version.)

ESC: Enter the menu (password may be required).

Line 1 shows messages, and Line 2 shows the disk status. The displayed
emergent info is listed below:

3.2.4 Background task messages

Background tasks and their process percentages are displayed in Line 1.
Line 2 shows the disk status. Message formats are listed in the following.

Variables:

xx.yy : xx is the DG identifier; yy is the LD identifier.

dgx : DG identifier.

zz / HDD z : HDD identifier.

xx.x% : The progress of task (with percentage estimate)

Emergent Info

Message

Note

Voltage failure

Voltage Failure

Power failure

Power Failure

Fan failure

Fan Failure

Temperature sensor
failure

Temp Failure

Temperature warning is not
included.

BBM failure

BBM Failure

Only when BBM is present.

Disk SMART warning

SMART Warning

Disk BBR error

Disk BBR Error

DG with degraded LD
and no rebuild task

DG+Degraded LD

DG with faulty LD

DG+Faulty LD

UPS On Batt

UPS On Batt

Only when upsconfig is on.

UPS connection is lost

UPS Con Lost

Only when upsconfig is on.

UPS should be replaced

UPS RB

Only when upsconfig is on.

UPS is overload

UPS Overload

Only when upsconfig is on.

UPS is off

UPS Off

Only when upsconfig is on.

Table 3-2 List of emergent messages