7 redundant controller configurations, 1 mirrored write cache control, 2 change preferred controller – Accusys ExaRAID GUI User Manual

Page 161: 3 path failover alert delay, 4 controller fallover mode, 8 event management, 1 nvram event logs

Advertising
background image

Using the CLI Commands

4-30

4.7 Redundant Controller Configurations

4.7.1 Mirrored write cache control

4.7.2 Change preferred controller

4.7.3 Path failover alert delay

4.7.4 Controller fallover mode

4.8 Event Management

4.8.1 NVRAM event logs

Command

cachemirror

Synopsis

cachemirror [on/off]

Description

Show or change the setting of mirrored write cache control.

Parameters

[on/off]: enable or disable mirrored write cache

Command

prefctlchg

Synopsis

prefeclchg [-o] jbdx/dgxldy/volx ctlx

Description

Change the preferred controller of a virtual disk.

Parameters

[-o]: change owner controller immediately

Command

foalertdelay

Synopsis

foalertdelay [xxmin]

Description

Set the delay period before the controller generates a
warning event to notify users of the critical condition that
virtual disks transferred to the non-preferred controller.

Command

Failovermode

Synopsis

Failovermode mpio / mtid

Description

Sets the failover mode to Mutipath IO (mpio) or Multiple-ID
(mtid). Without any parameter, this commond display
current setting. By default, the failover mode is mpio.

Command

eventlist

Synopsis

eventlist [-f xx] [-n xx] [-s severity]

Description

List records in the event log from older to newer records.

Parameters

[-f xx]: starting point of event to list

[-n xx]: maximum number of records to list

[-s severity]: severity level of records to list

Advertising