3 event handling – Accusys ExaRAID GUI User Manual

Page 163

Advertising
background image

Using the CLI Commands

4-32

4.8.3 Event handling

Command

eventmailconfig

Synopsis

eventmailconfig [-j subject] [-r xmin] [-d xsec] [-c content]

Description

Display or set the event mail configurations.

Parameters

[-j subject]: event mail subject

[-r xmin]: event mail retry period

[-d xsec]: event mail delay time

[-c content]: event mail content

Command

snmptraprcv

Synopsis

snmptraprcv set rcvx server port version community severity

snmptraprcv reset rcvx

Description

Enable or disable the specified SNMP server for SNMP trap
notification receiver.

Parameters

set/reset: set or clear receiver

rcvx: receiver identifier

server: SNMP server address

port: SNMP server port number

version: SNMP protocol version

community: SNMP community name

severity: severity level to notify

Command

snmptraptest

Synopsis

snmptraptest rcvx

Description

Send a test SNMP trap to the specified server.

Command

snmpagent

Synopsis

snmpagent on [-p port] [-c community]

Description

Enable or disable the SNMP agent which allow SNMP
browser to obtain information from the controller.

Parameters

[-p port]: SNMP agent port number

[-c community]: SNMP community name

Command

autowritethrough

Synopsis

autowritethrough [on/off ctl/bbm/pow/fan/ups]

Description

Review or set the auto write-through function.

Parameters

ctl/bbm/pow/fan/ups: controller failure, battery backup
module failure, power supply unit failure, fan failure, or UPS
failure

Advertising