RS422 #1 - #6

Description

Specifies what type of device/controller is connected to each
RS422 port of the EVS server.

Values

The following values can be available if the required license
codes are active:

'EVS Remote' for LSM Remote Panel (code between 103
and 109).

'EVS Remote' for XSense Remote Panel (code between
103 and 109 or code 96)

'EVS IPDP' (code 120 or 121)

'Sony BVW75' (code 118)

'XtenDD35' (code 118)

'Odetics' (and 'Odetics FK)' (code 119)

'VDCP' (and 'VDCP FK)' (code 119)

'EVS AVSP' (code 120 or 121)

'Edit Rec' (code 122)

'LinX' (code 123)

'Touch screen'

Default

On port #1 (only): IPDP

Rules

The following rules are applicable for assigning the following
controlling devices to RS422 ports:

A touch screen can only be assigned to port 6.

Note

Odetics FK and VDCP FK are not available directly from the Port setting, but
when the Odetics or VDCP protocols are assigned to an RS422 port, the Fill and
Key modes are available on the Main Ctrl field in the Channels and Control
settings.

Channels and Control Settings

Introduction

The Channel and Control settings mainly allow specifying which controllers (main and
possibly secondary) have the hand on which play or record channels.

These fields are available in the following interfaces:

in the Multicam Configuration window, Channels tab, in the advanced display mode
on page 1 on the server- and web-based interfaces.

in the Technical menu of the Remote Control Panel (T2.3 to T2.6).