How to activate the tally function, Tally, Add clip to pl – EVS XT2 Version 11.01 - November 2012 Configuration Manual User Manual
Page 176: Clips guardbands
How to Activate the Tally Function
To use the tally function, proceed as follows:
1. Activate it using the Tally parameter.
2. Go to the GPIs IN settings area and select the GPI IN used for the tally control.
3. Set the Channel/Device on the REC on which the Director’s Cut is performed.
4. Set the function as Mark Tly.
The tally function is now active, and works as follows:
When the server receives a ‘Mark tally’ GPI IN, an IN point is marked on the
corresponding record train (for ex. cam a). When a second ‘Mark Tally’ GPI IN is received
on a different record train (for ex. cam b), the server marks an OUT point on the first record
train (cam a) and an IN point on the second record train (cam b). All the clips created this
way are added to the defined playlist.
Tally
Description
Activate or deactivate the tally function.
Values
Yes/No
Default Value
Yes
Add Clip to PL
Description
Selects the LSM ID of the playlist to which the tally clips will
be added.
Values
10 to 99
Default Value
99
Clips guardbands
Description
Specifies the guardbands length of the tally clips, in seconds.
Values
0 to 250
Default Value
0
XT2 Server - Version 11.01 - Configuration Manual
3. Multicam Configuration
166