Power supply failure, Installing a power supply – Acer AB460 F1 User Manual

Page 101

Advertising
background image

81

Power Supply Failure

If a power supply or a fan in a power supply fails, the system
management software will notify you of the situation. In either case,
you will need to replace the power supply module with another
identical one.

Installing a Power Supply

1. Insert a replacement unit into the empty power bay with the

handle to the left.

Warning! This left/right orientation depends on the power
supply’s top or bottom location. If you inadvertently put a
power supply upside down in the lower slots, it can be
VERY difficult to remove the power supply.

2. Push unit all the way in until it is firmly seated.

3. Push the handle back into the closed position until it clicks into the

locked position.

4. Move the locking clip away from the socket and reconnect the

power cord.

Input AC Range

200-240VAC

Operating
Conditions

Temp: -5 to 50 C
Humidity: 5 to 95% RH

Fan Type

4x 90mm fans
- PFB0912DE-9E69
(8000 RPM)
- QFR0912UHE-9E70
(8800 RPM)