Read command: NOT

SUPPORTED

1:CMD ERR if read command is

issued
5:ACCESS ERR if insufficient access
level

Set command: EPDCC=1

0:OK if execution ok
2:PARAM ERR if parameter not equal

to 1

EPDCC (Empty Pipe Detection

Calibration Command) Executes the
calibration of the empty pipe
detection circuit.

Help command: EPDCC=?

1:EXECUTE

if accepted

Read command: SZPCC?

0 if the calibration is terminated

1 if the calibration is in progress
5:ACCESS ERR if insufficient access

level

Set command: SZPCC=1

0:OK if execution ok
2:PARAM ERR if parameter not equal

to 1
5:ACCESS ERR if insufficient access

level

SZPCC

(Sensor

Zero

Point

Calibration Command) Executes the
calibration of the sensor zero point.

Help command: SZPCC=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access

level

Read command: NOT
SUPPORTED

1:CMD ERR if read command is
issued

5:ACCESS ERR if insufficient access
level

Set command: SZPCR=1

0:OK if execution ok

2:PARAM ERR if parameter not equal
to 1

5:ACCESS ERR if insufficient access
level

SZPCR

(Sensor

Zero

Point

Calibration Reset) Resets the zero

point calibration value evaluated
with the preceding instruction

SZPCC.

Help command: SZPCR=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

COMMANDS AND FUNCTIONS EQUIVALENT TO THE “2-SCALES” MENU

Name and description

Modes

Returned values or codes

Read command: FRMUT?

Value of measure unit if accepted

5:ACCESS ERR if insufficient access
level

Set command: FRMUT=

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

FRMUT (Flow Rate Measure Unit

Type) Reads or sets the type of
measure units relative to the flow
rate. Possible values are:

0:VM = Volume, Metric
1:WM = Weight, Metric

2:VI = Volume, Imperial or American
3:WI = Weight, Imperial or American

Help command: FRMUT=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access

level

Read command: FRMUV?

Value of measure unit if accepted
5:ACCESS ERR if insufficient access

level

Set command: FRMUV=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

FRMUV (Flow Rate Measure Unit
Value) Reads or sets the value of

measure units relative to the flow
rate.

Help command: FRMUV=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access
level