Read command: FRFS1?

Value of flow rate full scale 1 if accepted

5:ACCESS ERR if insufficient access
level

Set command: FRFS1=

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

FRFS1 (Flow Rate Full Scale 1)

Reads or sets the value of flow rate
full scale 1.

Help command: FRFS1=?

min <> max (units)

if accepted

5:ACCESS ERR if insufficient access

level

Read command: FRFS2?

Value of flow rate full scale 2 if accepted
1:CMD ERR if full scale 2 not enabled

5:ACCESS ERR if insufficient access
level

Set command: FRFS2=

n

0:OK if parameters accepted

1:CMD ERR if full scale 2 not enabled
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

FRFS2 (Flow Rate Full Scale 2)
Reads or sets the value of flow rate

full scale 2.

Help command: FRFS2=?

min <> max (units)

if accepted

1:CMD ERR if full scale 2 not enabled
5:ACCESS ERR if insufficient access

level

Read command: VTMUT?

Type of measure unit if accepted
5:ACCESS ERR if insufficient access

level

Set command: VTMUT=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

VTMUT (Volume Totalizer Measure
Unit Type) Reads or sets the type of

measure units relative to the
totalizers. Possible values are:
0:VM = Volume, Metric

1:WM = Weight, Metric
2:VI = Volume, Imperial or American

3:WI = Weight, Imperial or American

Help command: VTMUT=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access
level

Read command: VTMUV?

Value of measure unit if accepted

5:ACCESS ERR if insufficient access
level

Set command: VTMUV=

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of rang

5:ACCESS ERR if insufficient access

level

VTMUV (Volume Totalizer Measure

Unit Value) Reads or sets the value of
measure units relative to the

totalizers.

Help command: VTMUV=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access

level

Read command: VTDPP?

Value of decimal digits if accepted
5:ACCESS ERR if insufficient access

level

Set command: VTDPP=

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

VTDPP (Volume Totalizers Decimal
Point Position) Reads or sets the

value representing the number of
decimal digits for representing the

volume totalizers.

Help command: VTDPP=?

min <> max

if accepted

5:ACCESS ERR if insufficient access
level