Burkert Type 8056 User Manual

Page 47

Advertising
background image

- 47 -

RS232_485_ETP_MODBUS_BU_REV02.doc

Help command: VTTPR=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

Read command: NOT

SUPPORTED

1:CMD ERR if read command is

issued
5:ACCESS ERR if insufficient access

level

Set command: VTPPR=1

0:OK if parameters accepted
2:PARAM ERR if

n

not equal to 1

5:ACCESS ERR if insufficient access
level

VTPPR (Volume Totalizer Partial

Positive Reset) Resets the partial
positive volume totalizer.

Help command: VTPPR=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

Read command: NOT

SUPPORTED

1:CMD ERR if read command is

issued
5:ACCESS ERR if insufficient access

level

Set command: VTTNR=1

0:OK if parameters accepted
2:PARAM ERR if

n

not equal to 1

5:ACCESS ERR if insufficient access
level

VTTNR (Volume Totalizer Total

Negative Reset) Resets the total
negative volume totalizer.

Help command: VTTNR=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

Read command: NOT

SUPPORTED

1:CMD ERR if read command is

issued
5:ACCESS ERR if insufficient access

level

Set command: VTPNR=1

0:OK if parameters accepted
2:PARAM ERR if

n

not equal to 1

5:ACCESS ERR if insufficient access
level

VTPNR (Volume Totalizer Partial

Negative Reset) Resets the partial
negative volume totalizer.

Help command: VTPNR=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

Read command: ENSDT?

Value of display on time if accepted

5:ACCESS ERR if insufficient access
level

Set command: ENSDT=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

ENSDT (ENergy Saving Display

Time) Reads or sets the value of
the display on time used in the

energy saving mode. This time is
also used to wait for the incoming

of new sms if they are enabled.

Help command: ENSDT=?

min <> max (units)

if accepted

5:ACCESS ERR if insufficient access

level

Read command: QSTME?

Status of functions if accepted

5:ACCESS ERR if insufficient access
level

Set command: QSTME =

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

QSTME (Quick STart Menu

Enable)

Help command: QSTME =?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access

level

Advertising