- 56 -

RS232_485_ETP_MODBUS_BU_REV02.doc

Help command: SUDIC=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access
level

Read command: NOT

SUPPORTED

1:CMD ERR if command is issued

SFDIC (Save Factory Defaults

Immediate Command) Saves the
current working parameters as

factory defaults preset data.

Help command: SFDIC=?

1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access

level

Read command: NOT

SUPPORTED

1:CMD ERR if command is issued

CMRIC (Complete Memory Reset

Immediate Command) Resets all
the working parameters to the

default values. WARNING: all the
current working parameters
eventually modified by the user

and the calibration coefficients
will be lost!

Help command: CMRIC=? 1:EXECUTE

if accepted

5:ACCESS ERR if insufficient access

level

Read command: SRNUM?

Value of serial number if accepted

5:ACCESS ERR if insufficient access
level

Set command: NOT
SUPPORTED

1:CMD ERR if command is issued

SRNUM (SeRial NUMber) Reads

the device serial number.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

Read command: TONTM?

Value of total on time if accepted

Set command: NOT
SUPPORTED

1:CMD ERR if command is issued

TONTM (Total ON TiMe) Reads
the total functioning time of the

device.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

Read command: CFFKT?

Value of the coefficient if accepted
5:ACCESS ERR if insufficient access

level

CFFKT (CoeFFicient KT) Reads or
sets the value of the gain coefficient

KT

Help command: CFFKT=?

min <> max

if accepted

5:ACCESS ERR if insufficient access

level

Read command: CFFKR?

Value of the coefficient if accepted
5:ACCESS ERR if insufficient access

level

Set command: CFFKR=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

CFFKR (CoeFFicient KR) Reads or
sets the value of the gain coefficient

KR

Help command: CFFKR=?

min <> max

if accepted

5:ACCESS ERR if insufficient access
level

Read command: CFFKS?

Value of the coefficient if accepted
5:ACCESS ERR if insufficient access
level

Set command: CFFKS=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

CFFKS (CoeFFicient KS) Reads or
sets the value of the gain coefficient
KS

Help command: CFFKS=?

min <> max

if accepted

5:ACCESS ERR if insufficient access
level