Burkert Type 8056 User Manual

Page 59

Advertising
background image

- 59 -

RS232_485_ETP_MODBUS_BU_REV02.doc

its technical measure unit. Returns

two comma-separated fields, the
technical unit symbol and the
numeric value.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

Read command: CUTPV? Returns

currency-symbol,value

string

1:CMD ERR if currency mode not

enabled

Set command: NOT
SUPPORTED

1:CMD ERR if command is issued

CUTPV

(CUrrency

Totalizer

Positive

Value) Reads the

converted currency value relative
to the partial positive totalizer and
its currency unit. Returns two

comma-separated fields, the unit
symbol and the numeric value.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

Read command: CUTNV? Returns

currency-symbol,value

string

1:CMD ERR if currency mode not
enabled

Set command: NOT

SUPPORTED

1:CMD ERR if command is issued

CUTNV

(CUrrency

Totalizer

Negative

Value) Reads the

converted currency value relative
to the partial negative totalizer and

its currency unit. Returns two
comma-separated fields, the unit

symbol and the numeric value.

Help command: NOT
SUPPORTED

1:CMD ERR if command is issued

Read command: AIN1V? Returns

measure-unit,value

string

1:CMD ERR if analog input 1 not
enabled

Set command: NOT
SUPPORTED

1:CMD ERR if command is issued

AIN1V (Analog INput 1 Value)
Reads the value of the analog
input 1 and its associated technical

unit. Returns two comma-
separated fields, the unit symbol

and the numeric value.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

Read command: BATTS? Returns

%,value

string

Set command: NOT

SUPPORTED

1:CMD ERR if command is issued

BATTS (BATTery Status) Reads
the estimated residual capacity of

the battery. Returns the percent
symbol and value separated by the

comma.

Help command: NOT
SUPPORTED

1:CMD ERR if command is issued

Read command: ALARM? Returns all active alarms in CSV format
Set command: NOT
SUPPORTED

1:CMD ERR if command is issued

ALARM (ALARM status) Reads
the alarm status of the instrument.
Returns a CSV list of all active

alarm.

Help command: NOT

SUPPORTED

1:CMD ERR if command is issued

AUXILIARY SET COMMAND

Name and description

Modes

Returned values or codes

Read command: ACODE?
Required access level: 2

String value if command accepted
1:CMD ERR if GPRS not enabled

5:ACCESS ERR if insufficient access level

Set command: ACODE
=

string

0:OK if parameters accepted
1:CMD ERR if GPRS not enabled

2:PARAM ERR if

string

out of range

5:ACCESS ERR if insufficient access level

ACODE (Access CODE)

Help command: ACODE

=?

NUMERIC RANGE if accepted

1:CMD ERR if GPRS not enabled
5:ACCESS ERR if insufficient access level

MODSV (MODel and Software

Version)

Read command: MODSV?

String value if command accepted

1:CMD ERR if GPRS not enabled
5:ACCESS ERR if insufficient access level

CLIST(Command LIST)

Read command: CLIST?

String value if command accepted

1:CMD ERR if GPRS not enabled
5:ACCESS ERR if insufficient access level