5.6.

PARAMETER SETTINGS

MODBUS PARAMETERS SETTINGS FOR THE CONVERTER:

• Menu «7-Communication», function - «Parity»: set the control of the parity for the byte frame in MODBUS

communication. This function affect all the serial port that communicate with MODBUS protocol. The possible
value are: EVEN (default), NONE and ODD.

• Menu «7-Communication», function - «RS485 pr.»: the function select protocol type for the RS 485 serial

port. Select the value MODBUS.

• Menu «7-Communication», function - «RS232 pr.»: the function select protocol type for the RS 232 serial

port. Select the value MODBUS.


Refer to the relative section of the serial port selected for the other type of parameter like port speed etc.


5.7.

STANDARD FUNCTIONS


For the MODBUS protocol, the converter ha the function of SLAVE device. The MASTER of the MODBUS network see

the Converter as a set of register of 1 bit or 16 bit.
The data are supplied with list of fixed address grouped in tables with different length.

FUNCTION 01, send of Status Batch. This command return variables of bit type.

Addresses(Hex format)

Bit Description

0000

1 = batch process is running, 0 = batch process

correctly terminated

0001

1 = batch process is suspended, 0 = batch
process is running or terminated

FUNCTION 03, send process data, data logger data, data logger events and batch memory. This

command return 16 bit variables that are linked to form floating-point (float) o 32 bit long-integer

(long) variables type. The high side of the word (MSW) is on even address, the low side of the
word (LSW) is in the immediately following address. The addresses are in HEX format.

NOTE: when the request is for the data of the data logger or the event logger that is
not valid (data not still collected), the returned value are = FFFFFFFF (hex).

Addresses table:

Addresses(Hex format)

Description

0000-0025

process data

0064-02E3

data logger value, grouped in 32 blocks contiguous
from 20 registries of memory to 16 bit for every block

03E8-04E7

data logger events, grouped in 64 blocks contiguous

from 4 register of memory to 16 bit for every block

07D0-084F

values of batch memories, grouped in 64 blocks

contiguous from 8 registers of memory to 16 bit for
every block

0BB8

index of the batch memory current in use

Process Parameters