- 99 -

RS232_485_ETP_MODBUS_BU_REV02.doc

If

(afByteReceveBuffer(76)

And

&H80) = &H80

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = min alarm temp. T2"

& vbCrLf

End

If


'Flags ML212

If

(afByteReceveBuffer(78)

And

&H1) = &H1

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = command error actuator"

& vbCrLf

End

If

If

(afByteReceveBuffer(78)

And

&H2) = &H2

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = deviation error"

& vbCrLf

End

If

If

(afByteReceveBuffer(78)

And

&H4) = &H4

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = Input error AIN1"

& vbCrLf

End

If

If

(afByteReceveBuffer(78)

And

&H8) = &H8

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = Input error AIN2"

& vbCrLf

End

If

If

(afByteReceveBuffer(78)

And

&H10) = &H10

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = manual regulation active"

& vbCrLf

End

If

If

(afByteReceveBuffer(78)

And

&H20) = &H20

Then

lblProcessData.Text = lblProcessData.Text &

"Process flags = safety mode active"

& vbCrLf

End

If

End

If

Catch

vObjExcept

As

Exception


vfStrErrorString =

"Form name: "

&

Me

.Name & vbCrLf & _

""

& vbCrLf & _

"Error source: "

& vObjExcept.Source & vbCrLf & _

""

& vbCrLf & _

"Error StackTrace: "

& vObjExcept.StackTrace & vbCrLf & _

""

& vbCrLf & _

"Error Message: "

& vObjExcept.Message


MsgBox(vfStrErrorString, MsgBoxStyle.OkOnly + MsgBoxStyle.Critical,

Me

.Text)

Return

End

Try

End

Sub



End

Class