RS232_485_ETP_MODBUS_BU_REV02.doc

Read command: CFFKZ?

Value of the coefficient if accepted

5:ACCESS ERR if insufficient access
level

CFFKZ (CoeFFicient KZ) Reads or

sets the value of the zero coefficient
KZ

Help command: CFFKZ=?

min <> max

if accepted

5:ACCESS ERR if insufficient access
level

Read command: ICALE?

Status of cal. error recognition if

accepted
5:ACCESS ERR if insufficient access

level

Set command: ICALE=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

ICALE (Ignore CALibration Errors)

Enables or disables the calibration
errors recognition.

Help command: ICALE=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access
level

Read command: C1CP1?

Value of the cal. point if accepted

1:CMD ERR if current output not
enabled

5:ACCESS ERR if insufficient access
level

C1CP1

(Current output 1

Calibration Point 1) Reads or sets
the value of the current output

calibration point 1 (4 mA).

Help command: C1CP1=?

min <> max

if accepted

1:CMD ERR if current output not
enabled

5:ACCESS ERR if insufficient access
level

Read command: C1CP2?

Value of the cal. point if accepted

1:CMD ERR if current output not
enabled

5:ACCESS ERR if insufficient access
level

C1CP2

(Current output 1

Calibration Point 2) Reads or sets
the value of the current output

calibration point 2 (20 mA).

Help command: C1CP2=?

min <> max

if accepted

1:CMD ERR if current output not
enabled
5:ACCESS ERR if insufficient access

level

Read command: A1CP1?

Value of the cal. point if accepted
1:CMD ERR if analog input not

enabled
5:ACCESS ERR if insufficient access

level

A1CP1 (Analog input 1 Calibration
Point 1) Reads or sets the value of

the current output calibration point
1 (4 mA or min. voltage value).

Help command: A1CP1=?

min <> max

if accepted

1:CMD ERR if analog input not

enabled
5:ACCESS ERR if insufficient access

level

A1CP2 (Analog input 1 Calibration
Point 2) Reads or sets the value of

the current output calibration point
2 (20 mA or max. voltage value).

Read command: A1CP2?

Value of the cal. point if accepted
1:CMD ERR if analog input not

enabled
5:ACCESS ERR if insufficient access

level