Burkert Type 8056 User Manual

Page 50

Advertising
background image

- 50 -

RS232_485_ETP_MODBUS_BU_REV02.doc

Read command: DLGSI?

Value of sample time interval if

accepted
1:CMD ERR if logging functions not
enabled

5:ACCESS ERR if insufficient access
level

Set command: DLGSI=

n

0:OK if parameters accepted
1:CMD ERR if logging functions not
enabled

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

DLGSI (Data LoGger Sample

Interval) Reads or sets the sample
time interval at which the data are
collected.

Help command: DLGSI=?

List of

num:description

if accepted

1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access

level

Read command: DTIME?

Value of date and time if accepted
1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access
level

Set command:
DTIME=

tmstring

Value of current date and time
1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access
level

DTIME (Date / TIME) Reads or
sets the date and time value.

WARNING: when setting the
date and time, always check
the value returned because

malformed input string may
lead to incorrect time result.

Help command: DTIME=?

Format of the string to be input
1:CMD ERR if logging functions not
enabled

5:ACCESS ERR if insufficient access
level

Read number of records:

DLDRD?

Number of records in memory if

accepted
1:CMD ERR if logging functions not

enabled

Read record: DLDRD=

n

Record

n

in CSV format if accepted

1:CMD ERR if logging functions not

enabled
2:PARAM ERR if

n

out of range

DLDRD (Data Logger static Data

ReaD) Reads the specified record,
the number of records saved in the

static data logger or the maximum
number of records that can be

saved in memory.

Read max. capacity:

DLDRD=?

Maximum range of

n

for the memory

in the format

min <> max

if

accepted

1:CMD ERR if logging functions not
enabled

Read command: NOT

SUPPORTED

1:CMD ERR if command is issued

DLDRE (Data Logger static Data

REset) Resets the static data logger
and clears all records.

Set command: DLDRE=1

0:OK if parameters accepted
1:CMD ERR if logging functions not

enabled 2:PARAM ERR if

n

not equal

to 1

5:ACCESS ERR if insufficient access
level

Advertising
This manual is related to the following products: