RS232_485_ETP_MODBUS_BU_REV02.doc

Read command: GSCLN?

Status of functions if accepted

5:ACCESS ERR if insufficient access
level

Set command: GSCLN =

n

0:OK if parameters accepted

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

GSCLN (GSm CaLl Number)

telephone number for GSM
connection

Help command: GSCLN =?

MAX 31 CHR STRING if accepted
5:ACCESS ERR if insufficient access

level

Read command: 485PT?

RS485 protocol type if accepted
1:CMD ERR if RS485 port not enabled

5:ACCESS ERR if insufficient access
level

Set command: 485PT =

n

0:OK if parameters accepted

1:CMD ERR if RS485 port not enabled
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

485PT (RS485 Protocol Type)
Reads or sets the protocol type for

the RS485 port: it can be DPP, HTP
or MODBUS. Valid only if the RS485

port is installed and enabled

Help command: 485PT =?

List of

num:description

if accepted

1:CMD ERR if RS485 port not enabled
5:ACCESS ERR if insufficient access

level

Read command: MODBP?

RS485 parity if accepted
5:ACCESS ERR if insufficient access

level

Set command: MODBP=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

MODBP (MODBus Parity) parity
control in MODBUS protocol

Help command: MODBP=?

List of

num:description

if accepted

1:CMD ERR if RS232 port not enabled
5:ACCESS ERR if insufficient access

level

COMMANDS AND FUNCTIONS EQUIVALENT TO THE “8-DISPLAY” MENU

Name and description

Modes

Returned values or codes

Read command: LLANG?

Layout language if accepted
5:ACCESS ERR if insufficient access
level

Set command: LLANG=

n

0:OK if parameters accepted
2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access
level

LLANG

(Layout

LANGuage)

Reads or sets the layout language
used for all the display messages.

Help command: LLANG=?

List of

num:description

if accepted

5:ACCESS ERR if insufficient access
level

Read command: NOT

SUPPORTED

1:CMD ERR if read command is

issued
5:ACCESS ERR if insufficient access

level

VTTPR (Volume Totalizer Total

Positive Reset) Resets the total
positive volume totalizer.

Set command: VTTPR=1

0:OK if parameters accepted
2:PARAM ERR if

n

not equal to 1

5:ACCESS ERR if insufficient access
level

Advertising