1 adding rly-6 modules, 2 configuring gpos, 24 configuring the e-fib fiber card – Clear-Com HX System Frames User Manual

Page 102: Adding rly-6 modules, Configuring gpos, Configuring the e-fib fiber card

Advertising
background image

Figure 5-9 GPOs Screen

5.23.1

Adding RLY-6 modules

To add / remove RLY-6 modules:

1)

Open Hardware > GPOs.

2)

The counter next to Number of External RLY-6 modules displays the current
number of RLY-6 modules. To display a drop-down list of numbers, click the
counter.

3)

If you select a higher number than the current number, new RLY-6 modules are
added. Six new GPOs are added per module.

4)

If you select a lower number than the current number, RLY-6 modules and their
associated GPOs are removed.

5.23.2

Configuring GPOs

In Hardware > GPOs, use the checkboxes to set whether the relay output is activated with
talk and or listen.

THE CONTROL MANAGER IS USED TO CREATE AND CONFIGURE CONTROLS THAT
CAN BE ATTACHED TO THE RELAYS.

5.24

Configuring the E-FIB fiber card

The E-FIB fiber card is designed to provide trunking between Eclipse HX-Omega, Eclipse
HX-Median and Eclipse HX-Delta matrices. The fiber cards can also be configured to
provide redundancy in communications link between Eclipse HX matrices. Each card
provides two fiber rings.

102

Eclipse EHX Software User Guide

Advertising
This manual is related to the following products: