Intelligent linking, Alias labels – Clear-Com HX System Frames User Manual

Page 45

Advertising
background image

Figure 3-14 Preferences tabs (open at Intelligent Linking)

Intelligent linking

Use this tab to:

• Specify the format of Alias Labels. Aliases mean that labels can be displayed

differently on a connected, remote system from the way they are displayed on the
local system.

• Define which ports are used for Comfort Tones (warning tones). Comfort tone

ports are used to indicate a trunking failure to panel users.

Alias Labels

This controls how labels for panel functions are presented in linked systems. The Alias
Labels options are as follows:

Options

Description

Same as the local label

Labels appear the same on local and remote
systems. If this option is selected the label be
the same regardless of whether it is on a local
system or on a remote system.

Local label prefixed with the system number

Local labels are prefixed with the system
number. This automatically indicates whether a
label on a panel operates on the local system or
on a remote system and the identity of the
remote system.

Freely editable

The labels may be set up with any system of
identification the user requires.

Table 3-3 Alias Labels Options

Note:

Because Partylines and Fixed Groups are now viewed as a global item across all systems
(they work inter-system), Partyline and Fixed Group alias names are not displayed in
remote systems. All Partylines and Fixed Groups should be given a unique name.

45

Eclipse EHX Software User Guide

Advertising
This manual is related to the following products: