5.21.5

IP port options

Note:

IP Port Options are only available for IVC-32 cards.

The IP port options are as follows:

UserID

Panel ID required for the panel to log in to the system via the IVC-32 card. The user ID is
set in EHX and also entered on the panel for the panel to log in.

Note:

The password must not contain upper case letters.

Network connection

Selects the network connection type for an IP panel. Select from LAN (high speed), WAN
(intermediate) or Internet (low speed) from a drop-down menu. The default ins LAN.

Audio codec

Allows the codec (G.722) to be selected for IP connections.

Password

Panel password required for the panel to log in to the system via the IVC-32 card. The
password is set in EHX and also entered on the panel for the panel to log in.

VOIP caller

Enables the port as the initiator of the VOIP setting.

Remote IP address

The IP address for the remote device

UDP comm. port

The UDP communication port for the remote device.

Remote user ID

The unique user ID for the remote device. The maximum length for a user ID is ten
characters including spaces.

Note:

The user ID is case sensitive.

Remote password

The password for the remote device. The maximum length for the password is ten
characters including spaces.

Note:

The password is case sensitive.

Applies to:

Only available on Concert and V-Series IP panels.