1 cable length, 2 description, 3 engineer comments – Clear-Com HX System Frames User Manual

Page 117: 4 label, 37 antenna role map, Cable length, Description, Engineer comments, Label, Antenna role map

Advertising
background image

5.36.1

Cable length

1)

To set the cable length between the card and the antenna select the Cable
Length
option and open the drop-down slider. User the mouse to adjust the cable
length setting from 0 - 129 meters to 2860 - 2989 meters.

The length set is displayed next to the option.

5.36.2

Description

Enter an optional description for the antenna such as position or function.

5.36.3

Engineer comments

A scratchpad for engineers to record any relevant information about the port or antenna.

5.36.4

Label

Label for the port used to assign the port to a path. The label has 10 characters, or can be
split into two parts, each of maximum five characters.

1)

To configure an E-Que card for Splitters select the card on the hardware list to
display the configuration screen.

In this case ten antennas are displayed corresponding to the two splitters that can be
connected to an E-Que card with each splitter supporting up to five antennas.

5.37

Antenna role map

Diagnostics > Antenna Role Map displays the status of the antennae and roles currently
configured.

Figure 5-25 Antenna and Role Display

The mapping of roles onto antennae is indicated by the colored squares. When a role is
registered to an antenna, a black dot is placed in the antenna row at the role position.

117

Eclipse EHX Software User Guide

Advertising
This manual is related to the following products: