26 e1 direct, 1 port function, 2 label – Clear-Com HX System Frames User Manual

Page 106: 3 description, 4 card properties, E1 direct, Port function, Label, Description, Card properties

Advertising
background image

Figure 5-12 E-Que Card Selection

Note:

A total of four E-QUE, IVC-32 or LMC-64 interface cards may be fitted to an Eclipse HX-
Omega.

5.26

E1 direct

The E1 Direct is an E-QUE card that has been configured for 60 direct ports using E1
protocol. Each E1 port can be used as an E1 communication line to another E1 device.
The following section provides guidance on configuring an E1 Direct in Cards and Ports.

5.26.1

Port function

This is always set to E1 Direct.

5.26.2

Label

Label for the port used to assign the port to a path. The label has 10 characters, or can be
split into two parts, each of maximum five characters.

5.26.3

Description

Optional port description, up to 255 characters long.

5.26.4

Card properties

For an E-QUE card in E1 Direct mode the Clock Recovery mode and Codec should be set
by clicking on the Card Properties link in the lower right of the hardware display. This
displays the Clock Recovery and Codec setup.

106

Eclipse EHX Software User Guide

Advertising
This manual is related to the following products: