• The Talk / Listen label as defined in EHX.

E-MADI64 card properties

Card Properties permits sample rate selection when synching to video signals. The E-
MADI64 card must be configured before it can be used when not using the Word Clock
Source Sync.

Card Properties always defaults to the E-MADI64 standard for the number of channels.

To set the sample rate parameters, click Card Properties on the lower right of the Matrix
Hardware display.

The following dialog is displayed:

Figure 5-34 MADI Channel Sample Rate

E-MADI channel mode

Sample rate

Configurable ports

32

96K

32

56

44.1K or 48K

56

64

44.1K or 48K

64, 32 or 16

Table 5-4 E-MADI Channel modes

5.43.3

Upgrading the E-MADI64 card firmware

You can upgrade the following E-MADI64 code with EHX:

• H8 application code (*.fwc format file).
• DSP code (*.fwc format file).
• FPGA code.

The boot code file (*.mot) is upgraded using the Renesas Flash Development Toolkit 3.4
Basic (FDT), not EHX. The FPGA code can also be upgraded using Xilinx iMPACT
programming software.

Note:

For detailed upgrade procedures and information, including upgrades that you cannot
perform in EHX, see the Eclipse HX Upgrade Guide.

To upgrade E-MADI64 H8, DSP or FPGA code (for all the E-MADI64 cards) using EHX:

1)

Ensure that you have the following equipment:

Equipment

Description / Notes

PC with an Ethernet or serial port

-

EHX software

EHX must be installed and configured

Ethernet or serial connection

For the matrix to PC connection

128