2 matrix event log, Matrix event log – Clear-Com HX System Frames User Manual

Page 270

Advertising
background image

• 2.1 dB
• 3.2 dB
• 3.9 dB
• 6.0 dB
• 8.9 dB
• 12.1 dB

The range for V-Series panels is -42 dB to +12 dB.

13.2

Matrix event log

In Live mode, messages are displayed in the Matrix Event Log as soon as they are
generated by the matrix. In offline mode, EHX makes a connection to the database. The
user sets search criteria and the resulting messages are displayed on screen.

The Matrix Event Log gives the EHX user information about the state of the matrix that is
helpful in diagnosing and repairing problems.

1)

Select the event types to be logged in the Properties pane by clicking on the
required checkboxes. The message types that can be selected for logging are
Critical, Warning and Information.

2)

Set the logging mode to Live to report current messages, or Historic to display
previous logged messages. In Historic mode the specific hour, minute, and
second beginning and end dates to search can be set. Click Display when these
parameters have been set to display the required log messages.

Figure 13-6 Event Log

3)

Use the Export option in the Properties pane to export the log messages to a file
for further processing.

Note:

The logging export file is an XML file and can be imported into Excel
using the speech quotes (“) as the delimiter.