Output gain

Allows the output gain level to be set. Use the output gain adjust slider control to set the
required gain from +15 dB to -45dB (or type in the value). The default is 0dB.

Sidetone gain

Sets the sidetone gain in dB for the panel. The default is 0dB.

Note:

Not available for V-Series, CCI-22, Concert, AES Mono, Panel Aux, Trunk, Direct and
FOR-22 interfaces.

Headset 2 microphone gain

Sets the gain in dB for the panel headset 2 microphone. The default is 50dB.

Note:

Not available for Concert, AES Mono, Panel Aux, Direct and FOR-22.

Headset microphone gain

Sets the gain in dB for the panel headset microphone. The default is 50dB.

Note:

Not available for Concert, AES Mono, Panel Aux, Direct and FOR-22.

Gooseneck microphone gain

Sets the gain in dB for the gooseneck (panel) microphone in dB. The default is 0dB.

Note:

Not available for Concert, AES Mono, Panel Aux, Direct and FOR-22.

Speaker dim

This is to prevent howl-round. When a talk selector is activated on a panel, the speaker
volume is attenuated by the value set within speaker dim.

To change the setting select the box with the current setting to display the slider and use
the mouse to drag the slider to the new setting. The speaker dim can be adjusted from -
15dB to 0db. The default is -9 dB.

Applies to:

I-Series Panels.

5.21.11 Audible alert options

The various configurable audible alerts on panels are as follows:

Call signal tone

When checked, the Call Signal Tone enables an audible tone when a call signal is
received by the panel. The call signal can be used to signal an event on another panel.
The default setting is disabled.

Change or error tones

When checked, the Change or Error Tones announce whenever the configuration for that
panel has changed or when there is an error on the panel. When unchecked Change or
Error Tones is disabled. The default setting is disabled.