background image

Supply, Pressure, and Return Hydraulics

5-48

31200079

WARNING: Hot hydraulic fluid can cause severe burns. Wait for the

hydraulic fluid to cool before servicing any hydraulic
component.

WARNING: Relieve hydraulic pressure before servicing any hydraulic

component. Escaping hydraulic fluid under pressure can
penetrate the skin, causing death or serious injury.

(Ref. Fig. 5-31) The following procedure describes removal of the rear axle
stabilizer control valve.

1. Follow preparation procedures as outlined in Section 3 of this manual.

Be sure to follow the guidelines in this section detailed under “General
Hydraulic Maintenance Practices” on page 5-3.

2. Install brake pressure diagnostic port test gauge into brake diagnostic

port (see page 5-49).

3. While watching test gauge, press brake pedal numerous times until

pressure gauge reads 0 psi. Remove test gauge from diagnostic port.

4. Thoroughly clean the rear axle stabilizer control valve.

5. Disconnect intermediate wiring harness from the low brake pressure

switch and solenoid valve.

6. Tag and

slowly loosen all hydraulic hoses. Disconnect hoses and

bleed any remaining oil into appropriate container. Cap fittings and
hoses.

7. Remove the three (3) each capscrews (Item 21) and lockwashers (Item

22) securing the rear axle stabilizer control valve (Item 23) to the valve
plate.

8. Remove the rear axle stabilizer control valve from the machine and

take it to a clean area appropriate for further disassembly, cleaning,
and overhauling.