Adjustable O-ring Fittings

To install straight thread, adjustable O-ring fittings:

1. Check condition of O-ring and replace as necessary. Do not install a

fitting with a damaged O-ring.

2. Lubricate O-ring with clean hydraulic fluid.

3. Back off the locknut fully.

4. Screw fitting into port until backup washer contacts face of port.

5. Position fitting by unscrewing a maximum of one turn.

6. Hold the fitting in position with a wrench and torque locknut per Table

3-6.

Table 3-6: Torque for Adjustable O-ring Fittings

O-ring Plugs

To install straight thread O-ring plugs:

1. Check condition of O-ring and replace as necessary. Do not install a

plug with a damaged O-ring.

2. Lubricate O-ring with clean hydraulic fluid and torque per Table 3-7.

Table 3-7: Torque for O-ring Plugs

Size

SAE Port

Thread Size

Min. Torque Max. Torque

-2

5/16-24

60

in-lbs 70

in-lbs

-4

7/16-20

160

"

180

"

-6

9/16-18

25

ft-lbs 29

ft-lbs

-8

3/4-16

40

"

44

"

-10

7/8-14

58

"

63

"

-12

1 1/16-12

75

"

85

"

-16

1 5/16-12

109

"

121

"

-20

1 5/8-12

213

"

237

"

-24

1 7/8-12

238

"

262

"

SAE Port

Hollow Hex Head

Hex Head

Size

Thread Size Min. Torque Max. Torque Min. Torque Max. Torque

-2

5/16-24

30

in-lbs

40

in-lbs

85

in-lbs

95

in-lbs

-4

7/16-20

125

"

145

"

205

"

235

"

-6

9/16-18

210

"

230

"

25

ft-lbs

29

ft-lbs

-8

3/4-16

44

ft-lbs

48

ft-lbs

46

"

50

"

-10

7/8-14

70

"

80

"

85

"

95

"

-12

1 1/16-12

80

"

90

"

105

"

115

"

-16

1 5/16-12

129

"

141

"

154

"

166

"

-20

1 5/8-12

213

"

237

"

213

"

237

"

-24

1 7/8-12

238

"

262

"

238

"

262

"