Removal – Lull 1044C-54 Series II Service Manual User Manual

Page 260

Advertising
background image

Boom and Transfer

6-118

31200079

Fig. 6-120: Boom Extension Proximity Switch Operation

(Ref. Fig. 6-120) The switch operates by sending out a constant, high
frequency magnetic field a short distance from the oscillator end of the
switch. Eddy currents are produced in metal when the magnetic flux lines
pass through it. These eddy currents oppose the oscillations of the
magnetic flux lines and the oscillations stop. A sensor in the switch detects
if the oscillator is on or off and this gives the switch its on/off function.

Removal

Boom Extension
Proximity Switch

Fig. 6-121: Boom Extension Proximity Switch Assembly

Proximity Switch

Outer Boom Section

Middle Rear)

Boom Section

J

1259

Magnetic

Flux Lines

Oscillator

0

80

60

40

20

J

1145

1

#

Description

1

Inner Jam Nut

2

Proximity Switch

#

Description

3

Outer Jam Nut

4

Wire Harness

2

3

4

Advertising