Chapter 8

Reference

8–13

Parameter 552 – [A>CA Constant 3]
Parameter 502 – [B>CA Constant 3]

Use: Stores a constant for use by function blocks
Parameter Type: Setup
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: 0

Description: This parameter can be used to store a constant value for use
by the function blocks.

Parameter 553 – [A>CA Constant 4]
Parameter 503 – [B>CA Constant 4]

Use: Stores a constant for use by function blocks
Parameter Type: Setup
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: 0

Description: This parameter can be used to store a constant value for use
by the function blocks.

Parameter 554 – [A>Mult1 FB In]
Parameter 504 – [B>Mult1 FB In]

Use: Determines Multiply #1 Input parameter
Parameter Type: Setup
Program Terminal Units: None
Minimum Value: B–300/A–400
Maximum Value: B–503/A–553
Default Value: B–320/A–420

Description: This parameter specifies where the Multiply #1 function
block gets its input data. Input data can come from other functions on this
Adapter or from the Drive by using a CA Indirect parameter linked to the
desired information. A value outside the following ranges disables the
function block input:

CHAN B

CHAN A

300 – 319

400 – 419

350 – 369

450 – 469

500 – 503

550 – 553