Discrete input – Rockwell Automation 1395 Multi-Comm Hardware/Software User Manual

Page 15

Advertising
background image

Chapter 3

Configuration & Interfacing

3–4

Discrete Input

The MCA board has a single discrete input which can be programmed for
use in the Drive. Figure 3–2 shows this input and the parameters that
control its use.

Figure 3-2. Discrete Input

J5

1

2

Stop

3

4

J4

115VAC/24VDC
Select

Bit # Specifier

Parameter

520

Operator

519

0
1
2

15

518

300

301

314

J4

Position

Input

1 – 2
2 – 3

24VDC
115VAC

!

ATTENTION: The Start/Stop circuitry in this drive is
composed of solid-state components. If hazards due to
accidental contact with moving machine components or
unintentional flow of liquid, gas or solids exist, NEMA
standards require that a hardwired maintained contingency Stop
circuit such as the one shown at terminals 1–2 of J5 be used
with this Drive.

Position

Input Type

1 – 2

2 – 3

Table 3-A.

Discrete Input Voltage Select Jumper J4

24V DC

115V AC Input

Par Num

Par Type

518

519

520

Table 3-B.

Parameter Listing for Discrete Input

Setup

Setup

Setup

Description

Discrete Input Map

Parameter Bit# Specifier

Parameter Operator

Discrete Input Map Parameter (Par #518) – Determines which
parameter the discrete input will affect. Valid source parameters are 300 –
314.