Reference

8–3

Table 8-A. MCA Board Parameter Channel Assignments

300 – 306

307 – 313

314 – 319

320 – 349

350 – 356

357 – 363

364 – 369

370 – 399

500 – 520

521, 522

523, 524

525, 526

527 – 532

533 – 536

537, 538

539 – 548

549

If Channel

Is DH+

DH+ Section

DH+ Section

Common Section

Not Used

DH+ Section

DH+ Section

Common Section

Not Used

Common Section

Not Used

Common Section

DH+ Section

DH+ Section

Not Used

DH+ Section

DH+ Section

Common Section

Parameter

Numbers

Port B

If Channel

Is RIO

RIO Section

RIO Section

Common Section

Not Used

RIO Section

RIO Section

Common Section

Not Used

Common Section

Not Used

Common Section

RIO Section

Not Used

Not Used

RIO Section

Not Used

Common Section

400 – 406

407 – 413

414 – 419

420 – 449

450 – 456

457 – 463

464 – 469

470 – 499

550 – 570

571, 572

573, 574

575, 576

577 – 582

583 – 586

587, 588

589 – 598

599

Parameter

Numbers

Port A

Parameter Name Structure

The actual channel assignments for an MCA Board can be determined by
looking at the link protocol DIP switches or by the parameter name. The
example below shows a typical parameter name. Parameters that remain
the same regardless of link protocol do not contain the “Protocol
Identifier”.

Parameter 300:

B > ChA RIO In 1

Drive Port that
MCA Board is
located in

MCA Board
Channel

Protocol Identifier for “ChA”

Parameter description

Parameter Table Structure

Table 8–B contains an abbreviated listing of the MCA board parameters.
The parameters in the Adapter can be categorized into the following
general groups by parameter number:
S #300 – #306 Port B Channel A Source Parameters

S #307 – #313 Port B Channel B Source Parameters

Advertising