Chapter 3

Configuration & Interfacing

3–63

Day (1 – 31) – An integer value representing the day the trigger condition
was detected.
Hour (0 – 23) – An integer value representing the hour the trigger
condition was detected.

Second (0 – 59) – An integer value representing the second the trigger
condition was detected.

Millisecond – An integer value representing the 10’s of milliseconds in
which the trigger condition was detected.

Monitored Parameter Descriptor – An integer value used by
Allen-Bradley program terminals to display the proper units for the
monitored parameter.

Block #1: This Block contains data samples 0 through 33 for the trend
buffer specified in the BTW instruction.

BTR Instruction Length: 38 words
MSG Size in Elements: 38

BTR

Data Samples – The data samples are
specified in Drive Units and may need to
be scaled by the PLC Controller prior to
being used in the Program.

0

0

270

See Note

1

Data Sample #1

Data Sample #2

Data Sample #33

Block #2: This Block contains data samples 34 through 66 for the trend
buffer specified in the BTW instruction.

BTR Instruction Length: 38 words
MSG Size in Elements: 38

BTR

Data Samples – The data samples are
specified in Drive Units and may need to
be scaled by the PLC Controller prior to
being used in the Program.

0

0

270

See Note

2

Data Sample #34

Data Sample #35

Data Sample #36