Led indicators, Firmware location – Rockwell Automation 1395 Multi-Comm Hardware/Software User Manual

Page 9

Advertising
background image

Chapter 2

Introduction and Product Description

2–2

!

ATTENTION: Certain procedures in this manual require that
the drive “Not be running”. This assumes that the DC loop
contactor is de-energized and that the user has properly set up
the interface logic to meet this criteria.

Additional hardware allows for a separate discrete input to the Drive. The
input device (Pushbutton, selector switch, etc) is connected to terminal
block J5 and is jumper selectable (see table 2–A) for either a 115V AC or
24V DC input. The function and operation of this input is controlled by
parameter settings.

LED Indicators

The MCA board contains several LED’s used to provide status
information. LED DS1 indicates wheter the MCA board itself is faulted or
not faulted. LED’s DS2 and DS3 duplicate the function provided by the
LED’s on the Interface Plug. LED DS4 indicates the status of the Discrete
input. Tables 2–A and 2–B provide information on LED’s DS1 – DS4.

LED

State

DS2

Table 2-A.

LED Indicator Status for RIO and DH+ Communication

LED Green

LED Off

LED Blinking Green

LED Blinking Red

ChA

ChB

DS3

Function

Normal PLC Communications

No communication to PLC Controller

PLC is in Reset/Program/Test Mode

PLC Has Rack Inhibited

DS2

DS3

LED Yellow

LED Off

LED Blinking Yellow

LED Blinking Red

Normal DH+ Communications

MCA Board Faulted

No Communication over DH+

Duplicate Node Address on DH+ Link

RIO

DH+

LED

State

DS1

Table 2-B.

LED Indicator Status for Board and Discrete Input

LED Green

LED Off

Function

Normal Adapter Operation

Adapter is Faulted

DS4

LED Off

LED Green

Discrete input is Low

Discrete input is High

MCA Board
Status

Discrete Input
Status

Firmware Location

The MCA Board contains a microprocessor (U20) which is responsible for
controlling all board functions and features. This board contains firmware
version 1.xx (the “xx” designator may vary but does not affect information
in this manual). Figure 2–1 shows the physical location of the firmware
chip (UMA1). The setup and configuration data for the Adapter board is
stored in the EEPROM memory located on the main control board of the
Drive.

Advertising