Chapter 3

Configuration & Interfacing

3–58

Refer to the Drive instruction manual (1395–5.xx) for a complete
description of how Auto tuning operates.

This function requires the message header only. The status byte will
indicate the success or ineffectiveness of the request.

Autotune Update System Inertia

This function updates the Drives internal database with the system inertia
(parameter 703) and the maximum achieveable velocity loop bandwidth
(parameter 701) as calculated by the auto tune firmware and provides the
data to the PLC Controller in the BTR message.

PLC Block Transfer Data

BTW Instruction Length: 4
BTR Instruction Length: 8

PLC DH+ Data –

Write

Read

Size In Elements:

4

8

Processor Type:

PLC–5

PLC–5

Destination Address:

N15:–3

N15:0–7

Message Structure –

Message Header Information:
Word 1
: 0
Word 2: 0
Function Code, Word 3: 1037
Write Message Length, Word 4: 8 bytes

WORD

0

0

1037

8

BTW

BTR

0

0

1037

See Note

1

2

3

4

NOTE:

Word 4 of the BTR instruction is broken down into
two bytes. The High byte contains the status bits
per Table 3–H. The low byte contains the Drive
message length in bytes.

Parameter 701

Parameter Data

Parameter 703

Parameter Data

Message Operation – The AUTOTUNE UPDATE SYSTEM INERTIA
function updates the Drives internal database with the system inertia
(parameter #701) and maximum achievable bandwidth (Parameter #703) as
calculated by the auto tune firmware, and provides the data to the PLC
Controller in the BTR Message.