Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 126

Advertising
background image

The following information is displayed for RAID-1 and RAID-10 arrays:

COMMAND STATUS

Command: OK

stdout: yes

stderr: no

Before command completion, additional instructions may appear below.

Components

Primary

Secondary

Status

hdisk4

degraded

pdisk13

pdisk15

good

pdisk3

pdisk6

good

pdisk7

BlankReserved5Z

degraded

F1=HelpF2=Refresh

F3=Cancel

F6=Command

F8=Image

F9=Shell

F10=Exit

/=Find

n=Find Next

Status data is given for the array and for each mirrored pair of disk drives in the
array. The status values for the array are:

good

The status of all mirrored pairs is good.

exposed

The status of one or more mirrored pairs is exposed. No mirrored pair is
degraded.

degraded

The status of one or more mirrored pairs is degraded.

rebuilding

The status of one or more mirrored pairs is rebuilding. No mirrored pair is
exposed or degraded.

offline

One of the following conditions exists:

v

The status of one or more mirrored pairs is offline.

v

The first two member disk drives of the primary half are missing, and the
Split Array Resolution flag is set to Primary.

v

The first member disk drive of the secondary half is missing, and the
Split Array Resolution flag is set to Secondary.

unknown

Not enough configuration data is available to determine the state of the
array. Under these conditions, ignore the primary and secondary
designations and the array-pair status.

The status values for mirrored pairs are:

good

Both member disk drives of the mirrored pair are present and working.

106

User’s Guide and Maintenance Information

Advertising