Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 436

Advertising
background image

SRN

Problem

Possible Causes

40128

Description: A 128 MB SDRAM in the adapter card module has failed.

Action: Exchange the FRUs for new FRUs.

Possible FRUs:

128 MB SDRAM module
(99%)
(“Removing an
SDRAM Module of an
Advanced SerialRAID
Adapter” on page 329).

SSA adapter card (1%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).

42000

Description: Either no SDRAM module is present on the adapter card, or
the POST cannot determine the size of the existing SDRAM module.

Action: Install an SDRAM module of the correct size, or exchange the
existing SDRAM module for a new one of the correct size.

Possible FRUs:

SDRAM module (99%)
(“Removing an SDRAM
Module of an Advanced
SerialRAID Adapter” on
page 329).

SSA adapter card (1%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).

42200

Description: Other adapters on the SSA loop are using levels of
microcode that are not compatible.

Action: Install the latest level of adapter microcode onto all the other
adapters on this SSA loop.

User or service action.

42500

Description: The Fast-Write Cache Option Card has failed.

Action:

1. Exchange the cache card for a new one.

2. Switch on power to the using system.

3. If the original cache card contained data that was not moved to a disk

drive, new error codes are produced. Run diagnostics in System
Verification mode to the adapter. If an SRN is produced, do the
actions for that SRN.

Possible FRUs:

Fast-Write Cache Option
Card (98%)
(“Removing the
Fast-Write Cache Option
Card of an Advanced
SerialRAID Adapter” on
page 332).

SSA adapter card (2%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).

416

User’s Guide and Maintenance Information

|
|
|
|

|
|
|
|

|
|
|
|

Advertising