9. The following information is displayed:

Remove a Disk from an SSA RAID Array

Type or select values in entry fields.
Press Enter AFTER making all desired changes.

Entry Fields

SSA RAID Manager

ssa0

SSA RAID Array

hdisk3

Connection Address / Array Name

095231779F0737K

* Disk to Remove

+

F1=HelpF2=Refresh

F3=Cancel

F4=List

F5=Reset

F6=Command

F7=Edit

F8=Image

F9=Shell

F10=Exit

Enter=Do

Press F4 to list the disk drives.

10. A list of disk drives is displayed.

From the displayed list, select the disk drive that you want to remove.

11. If necessary, use the Identify function to find the disk drive that you want to remove

(see “Finding the Physical Location of a Device” on page 409).

12. Press Enter to remove the disk drive from the array.

13. If the Check light of the disk drive that you are removing is off, use the Set Service

Mode service aid to put that disk drive into Service Mode (see “Set Service Mode
Service Aid” on page 378).

If the Check light of the disk drive that you are removing is on, you do not need to
select Service Mode before you remove that disk drive.

14. Physically remove the disk drive. (See the service information for the device that

contains the disk drive, then return to here.)

15. Physically install the replacement disk drive. (See the service information for the

device that contains the disk drive, then return to here.)

16. If the disk drive is in Service Mode, reset Service Mode. (See “Set Service Mode

Service Aid” on page 378, then return to here.)

Chapter 15. Removal and Replacement Procedures

323