SRN

Problem

Possible Causes

SSA03

Description: The service aid was unable to open an hdisk. This problem
might have occurred because a disk drive has failed or has been
removed from the system.

Action: Do the actions described here:

1. Use the Configuration Verification service aid (see “Configuration

Verification Service Aid” on page 387) to determine the location code
of the SSA adapter to which the hdisk is attached. (For example, if the
location code of the hdisk is 00-03-L, the location code of the SSA
adapter is 00-03.)

2. Run the Link Verification service aid (see “Link Verification Service

Aid” on page 383) to the SSA adapter.

3. If a link failure is indicated by the service aid, go to “MAP 2320: SSA

Link” on page 445.

4. If no link failures are indicated, run diagnostics in System Verification

mode to each pdisk that is attached to the SSA adapter.

None.