Good housekeeping – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 253

Advertising
background image

Good Housekeeping

The items described here can help you ensure that your SSA subsystem works
correctly.

v

When you are installing your SSA subsystem, ensure that ssa_adm is set to an
address that is suitable for your installation.

v

Regularly view the mail messages or OPMSGs that are in the error log, to determine
whether the automatic error log analysis has detected any errors.

v

If the automatic error log analysis has detected errors, but the diagnostics do not
generate an SRN, run an error log analysis with the history option set. Type:

ssa_ela -l Device [-h timeperiod]

where

timeperiod

is the number of 24-hour periods.

Set

timeperiod

to include at least the 24 hours that preceded the error. For example,

if at 09:00 on Monday you find that the error log analysis has reported an error on
pdisk3 at 05:01 on Sunday, type:

ssa_ela -l pdisk3 -h 3

where

3

is the number of 24-hour periods. An SRN for the error is generated.

Note: The error occurred on Sunday. When running the error log analysis, you need

to include at least the 24 hours that preceded the error; that is, Saturday. In
this example, therefore,

timeperiod

includes Saturday, Sunday, and Monday.

v

If application programs fail, run diagnostics in Problem Determination mode to find
the SRN.

v

Have no concerns about events that occur in the error log, unless an application
program fails, or error log analysis generates an SRN.

Chapter 11. SSA Error Logs

233