Link Verification Service Aid

The Link Verification service aid helps you determine:

v

Which devices are connected to the SSA loop

v

Where an SSA loop has been broken

v

The status of the disk drives on that SSA loop

v

The location of enclosure faults that have been detected by the disk drives on that
SSA loop

To use the Link Verification service aid:

1. Select Link Verification from the SSA Service Aids menu (see “Starting the SSA

Service Aids” on page 376). The Link Verification adapter menu is displayed:

LINK VERIFICATION

802385

Move cursor onto selection, then press <Enter>.

nunu:ssa0

04-02

IBM SSA 160 SerialRAID Adapter (

nunu:ssa1

04-04

IBM SSA 160 SerialRAID Adapter (

nunu:ssa2

04-07

IBM SSA 160 SerialRAID Adapter (

F3=Cancel

F10=Exit

2. Select the adapter that you want to test.

The columns of information displayed on the screen have the following meanings:

v

The first column shows the adapter name. The format of the adapter name is:

systemname:adaptername

(for example,

nunu:ssa0

)

where:

systemname is the name of the using system that contains the SSA adapter.

adaptername is the adapter resource identifier.

v

The second column shows the adapter location code (for example,

04-02

).

v

The third column shows the description of the adapter (for example,

IBM SSA 160

SerialRAID Adapter

).

Note: If the adapter name is longer than the description field, the name is

shortened, as shown in the screen above.

Chapter 17. SSA Service Aids

383