Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 487

Advertising
background image

22. (from step 7 in MAP 2410: SSA Repair Verification, and from steps 3, 11, and 12

in this MAP)

RAID Checkout

You are now starting the RAID checkout procedure

a. Type

smitty ssaraid

and press Enter.

b. Select Change/Show Use of an SSA Physical Disk from the SSA RAID

Arrays menu.

Are any disks listed as “SSA physical disks that are rejected”?

NO

Go to step 28 on page 470.

YES

a. Run diagnostics in System Verification mode to all the disk drives that

are listed as rejected.

b. Run the Certify service aid (see “Certify Disk Service Aid” on

page 391) to all the rejected disk drives.

c. Go to step 27 on page 470.

23.

(from steps 4 and 35)

An array is preparing a RAID array copy, but a coupled pdisk cannot be detected.
All read and write operations to the array can complete normally. The array copy,
however, cannot be uncoupled until the missing disk drive has been replaced and
contains an exact copy of the data that is on the array.

a. Type

smitty ssaraid

and press Enter.

b. Select Array Copy Services.

c. Select List All Copy Candidates.

d. Note the hdisk that is in the Degraded copy state.

e. Return to the SSA RAID Arrays menu.

f. Select Change/Show Use of an SSA Physical Disk. The status of the disk

drives that are connected to the using system is displayed.

g. Go to step 24.

24. (from step 23)

Are any disk drives listed as “SSA physical disks that are rejected”?

NO

A disk drive has not been detected by the adapter. Go to step 25 on
page 468.

YES

a. Run diagnostics in System Verification mode to all the disk drives that

are listed as rejected.

b. Run the Certify service aid (see “Certify Disk Service Aid” on

page 391) to all the disk drives that are listed as rejected.

Chapter 18. SSA Problem Determination Procedures

467

|

|
|
|
|

|

|

|

|

|

|
|

|

|

|

||
|

|

|
|

|
|

Advertising