Table 2. Error Labels (continued)

Error Label

Error ID

Error Description

SSA_DEVICE_ERROR

FE9E9357

This error can be logged against the adapter or disk drive
resource.

When the error is logged against a disk drive, it indicates that
the adapter has detected a failure on the disk drive. It is
possible, however, that the failure was detected because the
disk drive was unavailable for a short period. Run the error log
analysis to determine whether the disk drive should be
exchanged for a new one.

When the error is logged against the adapter, it indicates that the
adapter has received a report of a status that is not valid. The
adapter cannot, however, determine which disk drive sent the
bad data. Run diagnostics to all SSA disk drives. If no failure is
found, the log might have been caused by a link error.

SSA_DISK_ERR1

1D2E2C3B

An SSA disk drive has received a command or parameter that is
not valid. This error might be caused by:

v

A software error in the adapter

v

A software error in the disk drive

v

A hardware error

SSA_DISK_ERR2

928F5165

The disk drive has performed an internal error recovery
operation. No action is needed.

SSA_DISK_ERR3

8BDD5B42

The disk drive has performed internal media maintenance. No
action is needed.

SSA_DISK_ERR4

F7863CFE

One of the following has occurred:

v

The disk drive has had an unrecovered hardware error.

v

The disk drive has had a hardware error that is now
recovered, but the disk drive is reporting that it might be going
to fail.

SSA_ENCL_ERR1

BD797922

Errors of this type are logged when an enclosure (for example, a
7133 Model D40 or T40) reports a failure. The SRN indicates the
service procedures that must be performed.

SSA_ENCL_ERR2

A5BED0BC

Errors of this type are logged when an enclosure (for example, a
7133 Model D40 or T40) reports that the ambient temperature is
outside the specified limits. The SRN indicates the service
procedures that must be performed.

SSA_HDW_ERROR

05F97A32

A hardware failure has occurred. Run diagnostics in Problem
Determination mode to determine which FRUs to exchange for
new FRUs.

SSA_HDW_RECOVERED

B3FF2B19

A hardware error has occurred that has been recovered by the
error recovery procedures. Run error log analysis to determine
whether a FRU needs to be exchanged for a new FRU.

Chapter 11. SSA Error Logs

223

:

:

:

:

:

:::
:
:

:::
:
:
:

:

: